When the roof at Staghead Designs contained several leaks, we visited their location to provide diagnosis. Ultimately, they decided to repair some pipe penetrations that were sealed improperly on the warehouse, which may have lead to further issues. They also decided to have their office reroofed.
In order to complete this process, we tore off the existing ag panels and installed a TB Metals 1-1/2”x16” 26 ga. deep black mechanical seam roof over Sharkskin Ultra SA on the entire roof. Their roof is a 1:12 slope and the panel installed was suggested by the manufacturer. We also installed new flush panel commercial style soffit and fascia, as well as new 6” raingutter.
Throughout the process, we discovered that one of the leaks was caused by the HVAC contractor running the condensate line through the exterior wall, underneath the existing roof panels. Through our roofing services, we were able to resolve the leaks and restore the roof to pristine condition. Staghead Designs will no longer have leak issues. In addition, the new aesthetic matches the new interior remodel they completed 1 year prior.